RIVAGE PM Firmware V6.61
RIVAGE PM Firmware / Editor / StageMix Compatibility
Follow the version compatibility chart in the link below to make sure that all firmware versions are compatible with CS-R10, CS-R10-S, CSD-R7, CS-R5, CS-R3, DSP-R10, DSP-RX, DSP-RX-EX, RPio622, RPio222, RIVAGE PM Editor, RIVAGE PM StageMix, and MonitorMix when you operate the RIVAGE PM system. Using an unsupported Editor/firmware combination may result in unexpected behavior.
For TWINLANe network cards to be updated simultaneously with their host device (HY256-TL, HY256-TL-SMF), install them into a corresponding slot. If any additional cards are installed after performing the update, please execute the update program again.
To update a Dante card (HY144-D, HY144-D-SRC), use the Dante Firmware Update Manager or the Dante Updater of Dante Controller.
Main Revisions and Enhancements
Fixed bugs in V6.61
- Solved a problem found in V6.60, in which the VSS4HD and NonLin2 plugins did not work correctly.
- Solved a problem found in V6.60, in which some parameters of the following plug-ins – Interphase/VSS4HD/NonLin2, etc. could not be selected for control using the Touch and Turn encoder.
- Solved a problem found in V6.60, in which the Reverb Time of the REV-X plug-in was shown incorrectly.
New features in V6.60
- Added Dynamic EQ6 plug-in.
- Added control of HA parameters for DM7/DM7 Compact.
- Added Digital Audio Labs Livemix Personal Monitor System devices to DANTE SUPPORTED DEVICE list.
- Now supports Waves WSG-Y16 V3 mini-YGDAI I/O Card.
Improvements in V6.60
- When multiple USB memory drives are connected to a console surface, it is now possible to switch between different USB volumes in the SAVE/LOAD menu.
- The default setting of +48V Main on the control surface has been changed to ON.
- The default setting of MONITOR SOURCE DEFINE has been changed to ST A.
Fixed bugs in V6.60
- Solved a problem in RIVAGE PM5 or RIVAGE PM3 V6.01 or later versions, where operating the Fn Encoder Knob to which a parameter such as HA Gain, HPF, LPF or Fader Level was assigned, would cause that parameter to jump to an unexpected value, when any wireless receiver was mounted as a Dante I/O device and wireless control was assigned to that channel.
- Solved a problem in RIVAGE PM V6.01 or later versions where in rare cases, the following error message may have been displayed - “Software Exception has been detected”, when selecting FET Limiter or Diode Bridge compressors for Channel Dyn2, followed by switching the Selected channel from Input to Output whilst in the DYNAMICS1/2 pop-up.
- Solved a problem in which recalling a Dante Preset from Dante Controller PC application software when the RIVAGE PM system contains a high number of mounted Dante I/O devices, could result in some channels being unpatched and HA parameters would not be displayed correctly in the SELECTED CHANNEL and 12-Channel VIEWS. Please note that following a Dante Preset recall, it may take approximately 1 minute for the system to fully refresh all Dante patch and channel HA information.
- Solved a problem with the H3000Live plug-in that caused incorrect metering to be displayed.
- Solved a problem in which recalling a channel library to a channel patched to an RPio input port would cause the HA parameter values to be recalled to a lower-numbered channel, when that channel was patched to an input port of a different io device with the same port number as the original channel.
- Solved a problem in which when a User Defined Key was used as the Trigger of a Macro, pressing the USER DEFINED key would not execute the Macro following a Scene Recall.
- Corrected the default parameter values for the Dynamics type of Matrix channels.
- Fixed a problem in which the SELECTED CHANNEL VIEW screen and the OUTPUT PATCH screen might display incorrect values for the Patch or Port names when a Dante I/O device is patched to an output channel. If the problem has already occurred, it can be resolved by updating to V6.60 or later and unmounting and remounting the Dante I/O device.
Known issues
- When the SAVE/LOAD screen is displayed in RIVAGE PM V6.60, and a USB storage device is inserted, after it is removed the Windows User folder may very rarely be displayed in the folder path.
- If this happens, the problem can be temporarily avoided by re-displaying the SAVE/LOAD screen in a different bay (not applicable to CS-R3).
- To otherwise resolve the problem, the console will either need to be rebooted, or reset using the button on the rear panel.
- In a RIVAGE PM system with the Rio series mounted, the Dante INPUT PATCH might disappear upon powering on. Additionally, when this issue occurs, the current HA GAIN parameters on the control surface may be reflected in the Dante I/O devices, regardless of the RECALL SAFE setting. This issue can be avoided by turning on the power of the Rio series before turning on the RIVAGE PM system.
- When a configuration file created with RIVAGE PM Editor, including settings for mounting the Rio series, is loaded into the RIVAGE PM system, the mounted Rio series will remain in “Discovering” status and does not become controllable. However, control over parameters such as HA Gain is still possible. Restarting the power of the Rio series resolves this problem.
Notices in version updating
- When updating CS-R5 from V4.00, the touch panels may not respond when the update is completed. If this happens, skip the proper shutdown procedure and turn the power switches off and back on again. The console will operate normally once correctly updated to V5.00.
- When updating console or DSP firmware, the progress bar may stop or the update may close with an error. If this continues for 10 minutes or longer, turn the power to the device off and on, and then retry the firmware update.
- It is not possible to update DSP-RX(-EX) when using DSP Mirroring and the engine is in ‘Standby’ state. Please set DSP-RX(-EX) to ‘Active’ state and then proceed with the update.
- The project file saving method has been changed from V1.20.
When loading a project file saved by V1.16 or earlier, the patching of plug-ins may be unintentionally removed. If this happens, manually patch them again. - When loading a project file saved by V1.21 and earlier, the RACK Focus status indicator on the SCENE screen may not light even if effect plug-ins or GEQs are the target of Focus Recall. To indicate the Focus status properly, open the SCENE SETUP (FOCUS) pop-up screen once, and then close it. After doing this, save the revised project file to remove this problem in the future.
Notices in version downgrading
- Do not load a project file saved by V1.51 and later to a system running V1.21 and earlier. When loading, all plug-ins will be un-mounted in all Scenes including the current memory. In this case, re-mounting and setting up of parameters will be required.
- When downgrading the firmware, be sure to initialize all systems after downgrading.
- When loading data including the MixToInput settings of the V3.00 system, the MixToInput function will work in RIVAGE PM systems even of less than V3.00. However, be careful of the possibility of unwanted signal loops, etc.
Notices for usage
- The RIVAGE PM can only play back MP3 and WAV files whose file name is no longer than 60 single-byte characters or 20 double-byte characters excluding the extension. Please note that a file name exceeding this limit will not appear in the list on the RECORDER window.
- An error dialog “Console Network ring connection open! Check cable connection.” may rarely be displayed when the sampling rate is changed on the WORD CLOCK screen. However, it does not affect the actual operation.
- When INPUT patching is performed with the maximum number of channels of the HY256-TL or HY256-TL-SMF card exceeding 256, it appears to be correctly patched but no patch is established and no audio is input.
- In rare cases, a “DSP Disconnected!” message could be shown. If the message appears, take the following course of action:
- Re-Sync manually. Check this first for the fastest possible recovery (Doesn’t apply to RIVAGE PM7).
- If that doesn’t solve the problem, use the [RESET] button on the back of the console (Operations 1 and 2 do not mute the audio).
- If that doesn’t solve the problem, restart the console.
- If that doesn’t solve the problem, restart the DSP Engine (Doesn’t apply to RIVAGE PM7) (Operations 3 and 4 mute the audio).
- If you recall a Scene in which a very high HA gain was set, from a scene having a low HA gain, even if no signal is patched, a very loud pink noise signal is occasionally output for a few seconds.
- When a certain type of USB keyboard is connected to the console, the following message may appear:
You must restart your computer to apply these changes [Restart Now] [Restart Later]If this message is shown, remove this USB keyboard. It is not compatible with the console and cannot be used. The console does not need to be restarted.
- When a DSP mirroring failover occurs and the DSP engine B is set to active while the DSP engine A is the word clock leader and is still powered on, the Word Clock leader will not change automatically. To prevent audio dropouts, do not turn off the power of the DSP engine A even after a failover occurs.
- The channel name LCD cannot display unsupported characters such as Japanese kanji used in the Dante channel labels.
- If there are multiple DSPs in the same TWINLANe ring, or multiple HY144-D or HY144-D-SRC cards in the same Dante network in one DSP, only one of the cards should be enabled for SYNC TO EXTERNAL and that card should be set as the PTP LEADER.
- The Dante Domain Manager (DDM) SMPTE flow is displayed as AES67 to patch. There is no problem in the actual operation.
License Agreement and Download File
ATTENTION
PLEASE READ THIS SOFTWARE LICENSE AGREEMENT ("AGREEMENT") CAREFULLY BEFORE USING THIS SOFTWARE. YOU ARE ONLY PERMITTED TO USE THIS SOFTWARE PURSUANT TO THE TERMS AND CONDITIONS OF THIS AGREEMENT. THIS AGREEMENT IS BETWEEN YOU (AS AN INDIVIDUAL OR LEGAL ENTITY) AND YAMAHA CORPORATION ("YAMAHA").
BY DOWNLOADING OR INSTALLING THIS SOFTWARE OR OTHERWISE RENDERING IT AVAILABLE FOR YOUR USE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS LICENSE. IF YOU DO NOT AGREE WITH THE TERMS, DO NOT DOWNLOAD, INSTALL, COPY, OR OTHERWISE USE THIS SOFTWARE. IF YOU HAVE DOWNLOADED OR INSTALLED THE SOFTWARE AND DO NOT AGREE TO THE TERMS, PROMPTLY DELETE THE SOFTWARE.
GRANT OF LICENSE AND COPYRIGHT
Yamaha hereby grants you the right to use the programs and data files composing the software accompanying this Agreement, and any programs and files for upgrading such software that may be distributed to you in the future with terms and conditions attached (collectively, “SOFTWARE”), only on a computer, musical instrument or equipment item that you yourself own or manage. While ownership of the storage media in which the SOFTWARE is stored rests with you, the SOFTWARE itself is owned by Yamaha and/or Yamaha’s licensor(s), and is protected by relevant copyright laws and all applicable treaty provisions.
RESTRICTIONS
- You may not engage in reverse engineering, disassembly, decompilation or otherwise deriving a source code form of the SOFTWARE by any method whatsoever.
- You may not reproduce, modify, change, rent, lease, or distribute the SOFTWARE in whole or in part, or create derivative works of the SOFTWARE.
- You may not electronically transmit the SOFTWARE from one computer to another or share the SOFTWARE in a network with other computers.
- You may not use the SOFTWARE to distribute illegal data or data that violates public policy.
- You may not initiate services based on the use of the SOFTWARE without permission by Yamaha Corporation.
Copyrighted data, including but not limited to MIDI data for songs, obtained by means of the SOFTWARE, are subject to the following restrictions which you must observe.
- Data received by means of the SOFTWARE may not be used for any commercial purposes without permission of the copyright owner.
- Data received by means of the SOFTWARE may not be duplicated, transferred, or distributed, or played back or performed for listeners in public without permission of the copyright owner.
- The encryption of data received by means of the SOFTWARE may not be removed nor may the electronic watermark be modified without permission of the copyright owner.
TERMINATION
If any copyright law or provisions of this Agreement is violated, the Agreement shall terminate automatically and immediately without notice from Yamaha. Upon such termination, you must immediately destroy the licensed SOFTWARE, any accompanying written documents and all copies thereof.
DOWNLOADED SOFTWARE
If you believe that the downloading process was faulty, you may contact Yamaha, and Yamaha shall permit you to re-download the SOFTWARE, provided that you first destroy any copies or partial copies of the SOFTWARE that you obtained through your previous download attempt. This permission to re-download shall not limit in any manner the disclaimer of warranty set forth in Section 5 below.
DISCLAIMER OF WARRANTY ON SOFTWARE
You expressly acknowledge and agree that use of the SOFTWARE is at your sole risk. The SOFTWARE and related documentation are provided "AS IS" and without warranty of any kind. NOTWITHSTANDING ANY OTHER PROVISION OF THIS AGREEMENT, YAMAHA EXPRESSLY DISCLAIMS ALL WARRANTIES AS TO THE SOFTWARE, EXPRESS, AND IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS. SPECIFICALLY, BUT WITHOUT LIMITING THE FOREGOING, YAMAHA DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS, THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTS IN THE SOFTWARE WILL BE CORRECTED.
LIMITATION OF LIABILITY
YAMAHA’S ENTIRE OBLIGATION HEREUNDER SHALL BE TO PERMIT USE OF THE SOFTWARE UNDER THE TERMS HEREOF. IN NO EVENT SHALL YAMAHA BE LIABLE TO YOU OR ANY OTHER PERSON FOR ANY DAMAGES, INCLUDING, WITHOUT LIMITATION, ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, EXPENSES, LOST PROFITS, LOST DATA OR OTHER DAMAGES ARISING OUT OF THE USE, MISUSE OR INABILITY TO USE THE SOFTWARE, EVEN IF YAMAHA OR AN AUTHORIZED DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. In no event shall Yamaha's total liability to you for all damages, losses and causes of action (whether in contract, tort or otherwise) exceed the amount paid for the SOFTWARE.
THIRD PARTY SOFTWARE
Third party software and data ("THIRD PARTY SOFTWARE") may be attached to the SOFTWARE. If, in the written materials or the electronic data accompanying the Software, Yamaha identifies any software and data as THIRD PARTY SOFTWARE, you acknowledge and agree that you must abide by the provisions of any Agreement provided with the THIRD PARTY SOFTWARE and that the party providing the THIRD PARTY SOFTWARE is responsible for any warranty or liability related to or arising from the THIRD PARTY SOFTWARE. Yamaha is not responsible in any way for the THIRD PARTY SOFTWARE or your use thereof.
- Yamaha provides no express warranties as to the THIRD PARTY SOFTWARE. IN ADDITION, YAMAHA EXPRESSLY DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, as to the THIRD PARTY SOFTWARE.
- Yamaha shall not provide you with any service or maintenance as to the THIRD PARTY SOFTWARE.
- Yamaha is not liable to you or any other person for any damages, including, without limitation, any direct, indirect, incidental or consequential damages, expenses, lost profits, lost data or other damages arising out of the use, misuse or inability to use the THIRD PARTY SOFTWARE.
U.S. GOVERNMENT RESTRICTED RIGHTS NOTICE:
The Software is a "commercial item," as that term is defined at 48 C.F.R. 2.101 (Oct 1995), consisting of "commercial computer software" and "commercial computer software documentation," as such terms are used in 48 C.F.R. 12.212 (Sept 1995). Consistent with 48 C.F.R. 12.212 and 48 C.F.R. 227.7202-1 through 227.72024 (June 1995), all U.S. Government End Users shall acquire the Software with only those rights set forth herein
GENERAL
This Agreement shall be interpreted according to and governed by Japanese law without reference to principles of conflict of laws. Any dispute or procedure shall be heard before the Tokyo District Court in Japan. If for any reason a court of competent jurisdiction finds any portion of this Agreement to be unenforceable, the remainder of this Agreement shall continue in full force and effect.
COMPLETE AGREEMENT
This Agreement constitutes the entire agreement between the parties with respect to use of the SOFTWARE and any accompanying written materials and supersedes all prior or contemporaneous understandings or agreements, written or oral, regarding the subject matter of this Agreement. No amendment or revision of this Agreement will be binding unless in writing and signed by a fully authorized representative of Yamaha.
You Also Need
- HY144-D Firmware V4.2.3.1_3.1.1
- HY144-D-SRC Firmware V4.2.3.2_3.1.1
- RIVAGE PM Editor V6.6.1 for Mac macOS 14, 13, 12, 11(Intel/Apple silicon)
- RIVAGE PM Editor V6.6.1 for Win 11/10
- RIVAGE PM StageMix
- MonitorMix (iOS)
- MonitorMix (Android)
- RIVAGE PM Block Diagram
- RIVAGE PM series Data List
- RIVAGE PMシリーズ データリスト
- RIVAGE PM series V6 Operation manual [English]
- RIVAGE PM series V6 Operation manual [Deutsch]
- RIVAGE PM series V6 Operation manual [Español]
- RIVAGE PM series V6 Operation manual [Français]
- RIVAGE PM series V6 Operation manual [Italiano]
- RIVAGE PM series V6 Operation manual [한국어]
- RIVAGE PM series V6 Operation manual [Português]
- RIVAGE PM series V6 Operation manual [Русский]
- RIVAGE PM series V6 Operation manual [中文]
- RIVAGE PMシリーズ V6 オペレーションマニュアル
- RIVAGE PM10 System Setup Guide [English]
- RIVAGE PM10 System Setup Guide [Deutsch]
- RIVAGE PM10 System Setup Guide [Español]
- RIVAGE PM10 System Setup Guide [Français]
- RIVAGE PM10 System Setup Guide [Italiano]
- RIVAGE PM10 System Setup Guide [한국어]
- RIVAGE PM10 System Setup Guide [Português]
- RIVAGE PM10 System Setup Guide [Русский]
- RIVAGE PM10 System Setup Guide [中文]
- RIVAGE PM10 システムセットアップガイド
- RIVAGE PM7 System Setup Guide [English]
- RIVAGE PM7 System Setup Guide [Deutsch]
- RIVAGE PM7 System Setup Guide [Español]
- RIVAGE PM7 System Setup Guide [Français]
- RIVAGE PM7 System Setup Guide [Italiano]
- RIVAGE PM7 System Setup Guide [한국어]
- RIVAGE PM7 System Setup Guide [Português]
- RIVAGE PM7 System Setup Guide [Русский]
- RIVAGE PM7 System Setup Guide [中文]
- RIVAGE PM7 システムセットアップガイド
- RIVAGE PM StageMix User Guide [English]
- RIVAGE PM StageMix User Guide [Deutsch]
- RIVAGE PM StageMix User Guide [Español]
- RIVAGE PM StageMix User Guide [Français]
- RIVAGE PM StageMix ユーザーガイド
- MonitorMix User Guide [English]
- MonitorMix User Guide [Deutsch]
- MonitorMix User Guide [Español]
- MonitorMix User Guide [Français]
- MonitorMix ユーザーガイド
Installation Manuals
Previous versions
RIVAGE PM Firmware
- Previous versions information
- RIVAGE PM Firmware V6.60
- RIVAGE PM Firmware V6.11
- RIVAGE PM Firmware V6.10
- RIVAGE PM Firmware V6.01
- RIVAGE PM Firmware V5.14
- RIVAGE PM Firmware V5.13
- RIVAGE PM Firmware V5.12
- RIVAGE PM Firmware V5.11
- RIVAGE PM Firmware V5.10
- RIVAGE PM Firmware V5.03
- RIVAGE PM Firmware V5.01
- RIVAGE PM Firmware V5.00
- RIVAGE PM Firmware V4.72
- RIVAGE PM Firmware V4.71
- RIVAGE PM Firmware V4.22
- RIVAGE PM Firmware V4.21
- RIVAGE PM Firmware V4.14
- RIVAGE PM Firmware V4.13
- RIVAGE PM Firmware V3.05
- RIVAGE PM Firmware V3.04
- RIVAGE PM Firmware V3.03
- RIVAGE PM Firmware V3.02
- RIVAGE PM Firmware V3.01
- RIVAGE PM Firmware V3.00
- RIVAGE PM Firmware V2.52
- RIVAGE PM Firmware V2.20
- RIVAGE PM Firmware V2.02